Manufacturer & Exporter of Cables, Wires & PVC
Conduct Pipes. |

New Premium Product Range

R.K.
Electrical Industries (India) an ISO 9001-2008 Company manufacturers of "KALINGA®"
brand cables is one of the oldest & renounced name amongst the cable
manufacturing companies and has established itself in electric wires,
telecommunication. Coaxial cables, LT Power/Control Cables & PVC pipes.
The Company was established in the year 1955 by its founder Chairman
SH.S.L.Sethi, it was his dream, foresight, spirit, his formidable approach,
the experience, hard work, motivation of our professional team, the
infrastructure, marketing setup customer satisfactions our motive of
CONSISTENT
QUALITY-BETTER ECONOMY which has lead the company to such remarkable
heights.
Kalinga Electrical Industries has come up with a high quality products
keeping the ultimate safety factor in mind against fire and life, as the
concept of High Rise Buildings, Multiplexes, Modern Offices, Shopping Malls,
Air-conditioned Schools and Hospitals, Underground Metro Stations, Basement
Parking's etc has grown, so has the electrical installations in such
locations as they play paramount importance in providing the comfort level
of the people living or using such areas by the name
"KALINGA®
PLATINUM"
There is a consistent effort to maintain the quality of our products at
Kalinga Electrical Industries & is fully geared to maintain its
present position by updating the technology constantly and keeping abreast
of the development worldwide.
According to the latest study almost 99% of the wires & Cables are made
of PVC (Poly Vinyl Chloride) that emit > 20% of Halogen Gas, Therefore
PVC and its products are hazardous to human health and environment. It is
found that more than 80% of people killed in fire die due to suffocation and
even in some cases by inhalation of toxic gases. Burning of PVC generates a
thick dense smoke which blocks the exit signs and leads to suffocation in
that area. Also PVC emits corrosive and acidic gases while burning which can
lead to substantial damage in equipment. It also emits dioxins which can
cause Cancer.
Safety nowadays is the key issue for manufacturers and users of wires and
cables - be it safety in terms of human life, Safety in terms of toxic gases
or safety in terms of envi ronment.
Keeping in view all above factors, we have launched four exclusive products
as our motive has changed to
Consistant Quality - Better Safety.
Every product is being manufactured as per BIS standards or as perthe
specification of the customer
"KALINGA® PLATINUM" is the ultimate product so far as
the safety is concerned and comes in the following range:-
K-Platinum (HR-FR) |
Heat Resistant - Fire
Retardant |
K-Platinum (HR-FR 105o
C) |
Heat Resistant - Fire Retardant
(105o C) |
K-Platinum
(HR-FRLS) |
Heat Resistant - Fire
Retardant Low Smoke |
K-Platinum (HFLS) |
Halogen Free Low
Smoke |
Construction
Reference
Specification |
IS: 694 -1990, ASTM D
2863, ASTM D 2843, IEC-60754-1 etc. |
Voltage Grade |
1100 Volts. |
Conductor
Copper |
Electrolytic Grade
Bare Annealed Copperas per Flexibility class 1,2 & 5. of IS:
8130-1984. |
Insulation |
PVC type C of IS:
5831-1984 for conductor Temp. 85° C |
Colour of
Insulation |
Red, Yellow, Blue,
Black, Green, Grey & White. |
Insulation |
PVC Type A of IS : 5831-1984 for
Conductor Temperature 700C
PVC Type C of IS : 5831-1984 for Conductor Temperature 850C |
Packing |
90mtrs in Box Packing and 180/270
mtrs coils in Polywraps for projects. |
Technical
Comparison Between 105*C HRFR, HR-FRLS & HFLS Cables
S.
No. |
Features |
Standard
Range |
Special Range |
|
|
105°C |
HR-FRLS |
HFLS |
l. |
INSULATION PROPERTY |
GOOD |
GOOD |
EXCELLENT |
2. |
TEMP. RATING |
105DC |
105°C |
105°C |
3. |
THERMAL STABILITY |
GOOD |
GOOD |
GOOD |
4. |
FLAME RETARDANCY |
VERY GOOD |
VERY GOOD |
EXCELLENT |
5. |
SAFETY DURING BURNING |
GOOD |
GOOD |
EXCELLENT |
6. |
CRITICAL OXYGEN INDEX |
>29 |
>29 |
>35 |
7. |
TEMP. INDEX |
250'C |
>250°C |
>280X |
8. |
LIGHT TRANSMISSION
(VISIBILITY) During Cable Burning as per ASTMD-2843 (%) |
NA |
>40 GOOD |
>89 EXCELLENT |
9. |
RELEASE OF HALOGEN
GAS ON BURNING |
NA |
<20 |
<2 |
"KALINGA®
PLATINUM " Heat Resistant - Fire Retardant Cable (105° C)
lntroducing for the first time K-PLATINUM(HR-FR, 105°C)
Normal PVC used in cables are hazardous to human health and environment FR
Compound used in K-PLATINUM (HR-FR) has an advantage over ordinary PVC as it
has Fire retardent quality and are suitable for maximum operating
temperature of 70°C, but K-PLATINUM HR - FR (105°C) CAN operate
upto 105° C enhancing the life of electrical systems & thus
protects from short circuit due to overheating caused by over load.
Norminal
Area of Conductor |
No/Diameter
of Wires in Conductor |
Nominal
Thickness of Insulation |
Overall Diameter |
Maximum
D.C. Resistance at 20JC |
Current
Rating |
mm2 |
mm |
mm |
Mm |
Ohm/km |
Amps |
0.75** |
24/0.20 |
0.70 |
2.5 |
26.0 |
8 |
1.0* |
14/0.30 |
0.70 |
2.7 |
18.10 |
12 |
1.5* |
22/0.30 |
0.70 |
3.1 |
12.10 |
16 |
2.5* |
36/0.30 |
0.80 |
3.7 |
/ l |
22 |
4.0" |
56/0.30 |
0.80 |
4.3 |
4.95 |
29 |
6.0** |
84/0.30 |
0.80 |
4.8 |
3.30 |
37 |
10.0** |
140/0.30 or 80/0.40 |
1.00 |
6.6 |
1.91 |
45 |
16.0** |
126/0.40 |
1.00 |
7.8 |
1.210 |
60 |
25.0** |
196/0.40 |
1.20 |
9.7 |
0.780 |
75 |
35.0** |
276/0.40 |
1.20 |
10.9 |
0.554 |
95 |
50.0" |
396/0.40 |
1.40 |
13.2 |
0.386 |
125 |
Standard Packing - 90 mtrs. Project Packing -180 mtrs. Standard Colours -
Red, Blue, Yellow, Black, & Green (For Earthing). Confirming to IS:
694:1990. * As per conductor class 2 of IS 8130:1984 & " As per
conductor class 5 of IS 8130:1984.
"KALINGA
® PLATINUM" Heat Resistant - Flame Retardant Low Smoke (105°
HRFRLS)
FR PVC compound has better fire retardant properties than ordinary PVC but
its smoke and toxic gas emission is still much higher and has not served the
purpose of modern safety requirements. FRLS Compound offers better
properties for Flame retardant combined with lower smoke and acid fume
emission. It has been observed that maximum causalities in fire are caused
due to chocking and stampedes due to emission of highly toxic fumes of
hydrogen chloride acid gas, and has always been a threat to human in high
density areas as this reduces visibility thus hampers rescue operation.
K-PLATINUM (105°C, HR - FRLS) cables overcome this as they are low on
halogen contents which ensures better visibility and emition of non toxic
gases in case of an eventuality and also retards the spread of fire. The
consultants are now commonly specifying FRLS Wires.
K-PLATINUM (HR - FRLS) Single Core, Unsheathed Wires in Voltage Grade
1100V.
Norminal
Area of Conductor |
No/Diameter
of Wires in Conductor |
Nominal
Thickness of Insulation |
Overall Diameter |
Maximum
D.C. Resistance |
Current
Rating |
mm2 |
mm |
mm |
Mm |
Ohm/km |
Amps |
0.75** |
24/0.20 |
0.70 |
2.5 |
26.0 |
8 |
1.0* |
14/0.30 |
0.70 |
2.7 |
18.10 |
12 |
1.5* |
22/0.30 |
0.70 |
3.1 |
12.10 |
16 |
2.5* |
36/0.30 |
0.80 |
3.7 |
7.41 |
22 |
4.0** |
56/0.30 |
0.80 |
4.3z |
4.95 |
29 |
6.0a* |
84/0.30 |
0.80 |
4.8 |
3.30 |
37 |
10.0" |
140/0.30 or 80/0.40 |
1.00 |
6.6 |
1.91 |
45 |
Standard colours Red, Black, Yellow, Blue & Green (for earthling). As
per IS 3961 (PartV): 1986 supplied in 90 meter lengths in attractive
cartons. Confirming to IS: 694:1990. * As per conductor class 2 of IS
8130:1984 & ** As per conductor class 5 of IS 8130:1984.
Advantages
of "KALINGA ® PLATINUM" HR - FRLS H CABLES
Test |
Function |
Specification |
Typical |
Values |
|
|
|
HR - FRLSH |
PVC |
Critical Oxygen index |
To determine
percentage of oxygen required for supporting combustion of insulating
material at room temp. |
ASTM-D 2863 |
More than
29% |
23% |
Temp, index |
To determine at what
temp, normal oxygen content of 21% in air will support combustion of
insulating material |
ASTM-D 2863 &
BICC Handbook Chp No. 6 |
More than
250JC |
150°C |
Light Transmission
(Smoke density) |
To determine the
visibility (Light transmission) under Fire of insulating material. |
ASTM-D 2843 |
More than
40% |
10-15% |
Acid gas generation |
To ascertain the
amount of Hydrochloric acid gas evolved from insulation of cable under
fire |
IEC 754 -1 |
Less than
20% |
45-50% |
other tests carried
out are |
Flammability test |
As per IEC |
332-1 and
IS etc, |
694 : 1990 |
Properties/Comparison
between PVC, FRLS & HFLS
PROPERTIES |
PVC |
FRLS |
HFLS |
Halogen Gas, mg/g |
>200 |
150 |
<0.5 |
Corrosive Gas, ph |
1 -2 |
2-3 |
6 |
Smoke Density
(Rating) |
>70 |
50 |
<20 |
Usage Temperature,°C |
70 |
80 |
90 |
PROPERTIES |
PVC |
FRLS |
HFLS |
Dioxin |
yes |
yes |
no |
Toxic Halogen Gas |
yes |
yes |
no |
Lead |
yes |
yes |
no |
From above compar ision it is clearthat use of PVC wires is a big question
against Safety of Human Life and even against environment. "KALINGA®"
has introduced - ECO FRIENDLY NEW GENERATION (HALOGEN FREE LOW SMOKE) WIRES.
"KALINGA®
PLATINUM" (HFLS) CABLES - XTRA SAFE - ECO SAFE & MARK OF SAFTEY
Now a days FR (Flame Retardant) & FRLS (Flame Retardant Low Smoke)
wires are also widely used. Howeverthese FR/FRLS wires release Halogen,
Toxicand Corrosive gasscs in the event of fire causing a strong smell &
eventually lead to suffocation.
K-PLATINUM (HFLS) Halogen Free Cables are the final word in safety. These
cables are made of special compound which emits no Halogen gas on burning.
It has very low emission of non toxic & translucent gases in case of
fire, thereby maximizing chances of rescue. This is the ultimate product for
best safety and highly recommended for every important buildings mainly
Hospitals, Airports, Schools, Cinema Halls, Shopping Malls, Industries and
High rise domestic and commercial buildings. Refineries etc.
Norminal
Area of Conductor |
No/Diameter
of Wires in Conductor |
Nominal
Thickness of Insulation |
Overall Diameter |
Maximum
D.C. Resistance at 20oC |
Current
Rating |
mm2 |
mm |
mm |
Mm |
Ohm/km |
Amps |
0.75** |
24/0.20 |
0.70 |
2.5 |
26.0 |
8 |
1.0* |
14/0.30 |
0.70 |
2.7 |
18.10 |
12 |
1.5* |
22/0.30 |
0.70 |
3.1 |
12.10 |
16 |
2.5* |
36/0.30 |
0.80 |
3.7 |
/ l |
22 |
4.0" |
56/0.30 |
0.80 |
43 |
4.95 |
29 |
6.0** |
84/0.30 |
0.80 |
4.8 |
3.30 |
37 |
10.0** |
140/0.30 or 80/0.40 |
1.00 |
6.6 |
1.91 |
45 |
Standard colours Red, Black, Yellow, Blue & Green (for earthling). As
per IS 3961 (Part V): 1968 supplied in 90 meter lengths in attractive
cartons. Confirming to IS: 694:1990. "As per conductor class 2 of IS
8130:1984 & ** As per conductor class 5 of IS 8130:1984.
 |